Operation Manual D-480 ©BÜCH Labortechnik AG
3 - Product description 31
Analytical characteristics
Analytical characteristics
The following table explains the analytical characteristics:
Analytical characteristic
Analysis method Nitrogen determination from a sample according to Dumas.
Combustion of the samples, transfer to N
2
, separation of foreign
gases, thermal conductivity detection.
Standards Analysis method according to:
AOAC 99.03, AOAC 993.13, AOAC 968.06, AOAC 992.15,
AOAC 992.23, ASBC, AACC (for fertilizer, meat, meat products,
grain, oilseed, brewery grain, flour, animal feed),
DIN 10 467, milk and milk products,
EN 61010, DIN projected.
Detector Thermal conductivity detector (TCD).
Sample weight/sample volume Up to 1 g organic substance or approx. 1 ml sample volume
(depending on substance).
Dynamic work range 0.1 mg bis 200 mg N abs.
Precision Less than 0.5 % relative standard deviation with test substance
aspartic acid (sample weight: approx. 300 mg).
Detection limit 0.10 mg N abs.
Recovery rate Larger than 99.5 % for test substances.
Duration of analysis Self-optimizing, 4 to 6 minutes, depending on substance and
sample weight (e.g 5,5 min. for 0.4 g hay).
Calibration Linear and non-linear curve adjustment; total work range, if
applicable divided into two segments.
Data storage and data output Storage on hard disk or external storage media.
LIMS transfer possible.
Data output to screen and printer.
Technical specifications
Standardization
The instrument conforms to CE standards in accordance with EC Directives:
EMC 89/336/EEC
LVD 73/23/EEC
Control and data processing
The following table contains the technical specifications of the control and data processing system:
Control and evaluation unit PC with operating system Windows XP Professional or a newer
version of Windows Professional
Printer (optional)
Software German or English
Menu-driven
Status display during analysis
Real-time graphics