Page 2

2 Safety10 R-220 SE Operation Manual, Version FExplosive gases, explosive environmentHarmful to life-formsHot item, hot surfaceDevice damageInhalation

Page 3 - Table of contents

10 Spare parts100 R-220 SE Operation Manual, Version F10.3 Receiving vessel partsInterchangeable receiver (double)Part name Order no.Receiving flask

Page 4

10 Spare parts101 R-220 SE Operation Manual, Version FInterchangeable receiver D2 HPPart name Order no.Receiving flask 10 l plg 037569Branching piece

Page 5

10 Spare parts102 R-220 SE Operation Manual, Version F041095041094041231Set of distribution head seals (5 pcs.) 041231Seal holder 041094Vacuum seal 0

Page 6

10 Spare parts103 R-220 SE Operation Manual, Version F041110Metal reed (at gearbox flange) 041110041112Snap flange coupling, cpl. 041112041229Set of 5×

Page 7 - 1 About this manual

10 Spare parts104 R-220 SE Operation Manual, Version FStandard spare partsPart name Order no.11056381∅~ 30 mmSmall glassware jointPTFE coated silico

Page 8 - 2 Safety

Cover for evaporating flask, Ø 150 mm, PP042895Cover for evaporating flask, PE 11057349Spare parts for Basic versionPart name Order no.3-way PTFE va

Page 9 - SIGNAL WORD

11 Declarations and requirements106 R-220 SE Operation Manual, Version F11 Declarations and requirements11.1 FCC requirements (for USA and Canada)E

Page 10

11 Declarations and requirements107 R-220 SE Operation Manual, Version F11.2 Declaration of conformity

Page 12 - 2.5 Product safety

BÜCHI Labortechnik AGCH-9230 Flawil 1 / SwitzerlandT +41 71 394 63 63 F +41 71 394 65 65 www.buchi.com Quality in your hands

Page 13

2 Safety11 R-220 SE Operation Manual, Version FUse of water is mandatory (non-standard symbol)Wear protective maskWear laboratory coatWear protective

Page 14

2 Safety12 R-220 SE Operation Manual, Version F2.5 Product safetySafety warnings in this manual (as described in section 2.4) serve to make the user

Page 15 - 2.6 General safety rules

2 Safety13 R-220 SE Operation Manual, Version F NOTICERisk of instrument short-circuits and damage by liquids.• Do not spill liquids over the instrum

Page 16 - 3 Technical data

2 Safety14 R-220 SE Operation Manual, Version F2.5.3 Personal safety measuresAlways wear personal protective equipment such as protective eye goggles

Page 17

2 Safety15 R-220 SE Operation Manual, Version F2.6 General safety rulesResponsibility of the operatorThe head of the laboratory is responsible for tr

Page 18 - 3.2 Technical data

3 Technical data16 R-220 SE Operation Manual, Version F3 Technical dataThis chapter introduces the reader to the instrument and its specifications. I

Page 19 - Glass assembly

3 Technical data17 R-220 SE Operation Manual, Version F175 cm163 cm158 cm150 cm143 cmD D2 HP D2 DB2 DB RB R C3.1.1 Application areasThe Rotavapor R-

Page 20 - 3.3 Materials used

3 Technical data18 R-220 SE Operation Manual, Version F3.2 Technical dataTechnical data Rotavapor R-220 SEElectrical connection data, single phaseVo

Page 21 - 4 Description of function

3 Technical data19 R-220 SE Operation Manual, Version FTechnical data Rotavapor R-220 SEHeating bathHeating medium Depending on heating wattage3600 W

Page 23 - 4.2 Rotavapor front-side

3 Technical data20 R-220 SE Operation Manual, Version F3.3 Materials usedAll materials in contact with the product are FDA compliant!Materials usedC

Page 24 - 4.3 Tubing scheme

4 Description of function21 R-220 SE Operation Manual, Version F4 Description of functionThis chapter explains the basic working principle of the Ro

Page 25

4 Description of function22 R-220 SE Operation Manual, Version FHeating bath with heating liquidEvaporating solventRotation drive for evaporating flas

Page 26

4 Description of function23 R-220 SE Operation Manual, Version F4.2 Rotavapor front-sideVarious glassware configurations are available for the Rotava

Page 27

4 Description of function24 R-220 SE Operation Manual, Version F4.3 Tubing schemeVAPOR TEMP.CW TEMP.LEVEL 2LEVEL 2CW FLOWRESERVEINPUTRS-485RS-485

Page 28

4 Description of function25 R-220 SE Operation Manual, Version FVacuum / gas circuit1Vacuum pump (recommended type: Vacuum Pump V-710)For most applic

Page 29 - ** Optional accessory

4 Description of function26 R-220 SE Operation Manual, Version F4.3.1 Cooling water routingGeneral memory aid for cooling water routingIndependent o

Page 30 - (Type plate)

4 Description of function27 R-220 SE Operation Manual, Version F4.3.2 Vaccum routingGeneral memory aid for vacuum routingIndependent of the installe

Page 31

4 Description of function28 R-220 SE Operation Manual, Version FExample 2:Vapor temp. sensor End of cooling pathConnection to vacuum sourceConnection

Page 32

4 Description of function29 R-220 SE Operation Manual, Version F4.4 User interface front-side RotavaporR-220 SEStartStopON/OFFTemp.Heater Record Lif

Page 33 - 5 Putting into operation

Table of contents3 R-220 SE Operation Manual, Version FTable of contents1 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 34 - 5.2 Electrical connections

4 Description of function30 R-220 SE Operation Manual, Version F4.5 Connection field at the rear-sideabdfghijklmnceVAPOR TEMP.CW TEMP.LEVEL 2LEVEL

Page 35

4 Description of function31 R-220 SE Operation Manual, Version FdThe optional cooling water valve interrupts the water flow in order to effectively re

Page 36

4 Description of function32 R-220 SE Operation Manual, Version FkHardwired power connection to heating bath.lSee Operation Manual of the connected de

Page 37 - CW Flow

5 Putting into operation33 R-220 SE Operation Manual, Version F5 Putting into operationThis chapter describes how the instrument has to be installed

Page 38

5 Putting into operation34 R-220 SE Operation Manual, Version FNOTESecure the instrument against tilting and unintentional moving in earthquake prone

Page 39

5 Putting into operation35 R-220 SE Operation Manual, Version F5.3 Sensor setup and adjustmentsSensor setup menuThese instructions are valid for the

Page 40 - VAPOR TEMP

5 Putting into operation36 R-220 SE Operation Manual, Version F5.3.1 Level sensorsDescription of function:The capacitive level sensors are recommend

Page 41 - CW TEMP

5 Putting into operation37 R-220 SE Operation Manual, Version F5.3.2 Cooling water flow sensorThe switching threshold of the flow sensor can be adjust

Page 42

5 Putting into operation38 R-220 SE Operation Manual, Version F5.3.3 Foam sensorDescription of function:A foam sensor is highly recommended whenever

Page 43 - 5.6 Condenser clamps

5 Putting into operation39 R-220 SE Operation Manual, Version FAdjustment instructions• Make sure the foam sensor is installed correctly. Remove th

Page 44 - 5.7 EasyClamps

Table of contents4 R-220 SE Operation Manual, Version F5.11.2 Disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 45 - 5.8 Inlet valve

5 Putting into operation40 R-220 SE Operation Manual, Version F5.3.4 Vapor temperature sensorDescription of function:Enables the vapor temperature r

Page 46

5 Putting into operation41 R-220 SE Operation Manual, Version F5.3.5 Cooling water temperature sensorDescription of function:Enables the cooling wat

Page 47

5 Putting into operation42 R-220 SE Operation Manual, Version F5.5 Setting up the support rod(s)abcdaInstall the retaining bracket at the housing. F

Page 48

5 Putting into operation43 R-220 SE Operation Manual, Version F5.6 Condenser clampsabcFlat springaTurn the lever counterclockwise to loosen / open t

Page 49

5 Putting into operation44 R-220 SE Operation Manual, Version F5.7 EasyClampsEasyClamps can be found at glassware connections. EasyClamps can be clea

Page 50

5 Putting into operation45 R-220 SE Operation Manual, Version F5.8 Inlet valveThe inlet valve allows continous feeding and manual aeration (e.g. at

Page 51 - 5.13 Single receiver

5 Putting into operation46 R-220 SE Operation Manual, Version F5.9 Glassware and configurationsAll original glassware parts and accessories are of su

Page 52

5 Putting into operation47 R-220 SE Operation Manual, Version FAll sealings in contact with the product have a PTFE surface and can be disinfected in

Page 53

5 Putting into operation48 R-220 SE Operation Manual, Version FThe following concentrations per germ were applied for every contaminant:103 germs/ml1

Page 54

5 Putting into operation49 R-220 SE Operation Manual, Version FTest resultsContaminant Concentration germs/ml Sample 1 germs/ml Sample 2 germs/ml Sam

Page 55

Table of contents5 R-220 SE Operation Manual, Version F10.5 Optional equipment and upgrade parts . . . . . . . . . . . . . . . . . . . . . . . .10511

Page 56 - Set Temp

5 Putting into operation50 R-220 SE Operation Manual, Version FabcdeaStart with the distribution piece and mount it at the gearbox.bProceed with the

Page 57

5 Putting into operation51 R-220 SE Operation Manual, Version F5.13 Single receiverOutlet of glassware configurationAeration screw capEasyClamp (DN 2

Page 58 - CW VALVE

5 Putting into operation52 R-220 SE Operation Manual, Version FPreparational steps:• Install the appropriate glassware configuration between the gear

Page 59

5 Putting into operation53 R-220 SE Operation Manual, Version FDual receiverOutlet of glassware configurationAeration screw capEasyClamp (DN 25)Receiv

Page 60

5 Putting into operation54 R-220 SE Operation Manual, Version FPlace the first receiving flask on the support ring .➥ Keep the receiving flask upright w

Page 61

5 Putting into operation55 R-220 SE Operation Manual, Version F2×Install the draining valves with two EasyClamps (DN 25).5.14 Heating bath filling le

Page 62

5 Putting into operation56 R-220 SE Operation Manual, Version F5.15 Heating bath setup for 2×1800 W heating elementThe heating element holder is lab

Page 63

5 Putting into operation57 R-220 SE Operation Manual, Version FBasic heating transfer medium requirements• Do not use media which are corrosive agai

Page 64

5 Putting into operation58 R-220 SE Operation Manual, Version F5.15.1 Water as heating transfer mediumWith the heating bath in lowest position, inst

Page 65

5 Putting into operation59 R-220 SE Operation Manual, Version FaLevel drain with Ø 12 mm hose connector, let into sink.bDraining tap with Ø 12 mm hos

Page 67 - 5.21 Controller upgrade

5 Putting into operation60 R-220 SE Operation Manual, Version F5.16 Heating bath setup for 4.2 and 6.3 kW heating elementThe heating element holder

Page 68 - 6 Operation

5 Putting into operation61 R-220 SE Operation Manual, Version FBasic heating transfer medium requirementsDo not use water which is corrosive against

Page 69

5 Putting into operation62 R-220 SE Operation Manual, Version F5.17 Attaching and removing evaporating flasksEvaporating flasks are available in diffe

Page 70 - 6.3 Solvent table

5 Putting into operation63 R-220 SE Operation Manual, Version FdedPush down the unlock rocker at the left half of the snap flange.eOpen the snap flange

Page 71 - 7 Maintenance and repairs

5 Putting into operation64 R-220 SE Operation Manual, Version F NOTICERisk of instrument damage by wrong mains supply.• External mains supply must m

Page 72

5 Putting into operation65 R-220 SE Operation Manual, Version FAfter readjustment, perform a vacuum test-run without heating bath and sample medium.N

Page 73

5 Putting into operation66 R-220 SE Operation Manual, Version F5.20 Vacuum controller installation / removalabcaLift the small plastic reed at the

Page 74

5 Putting into operation67 R-220 SE Operation Manual, Version F5.21 Controller upgradeTo upgrade a basic Rotavapor with a controller proceed as foll

Page 75 - Vapor duct might slip out!

6 Operation68 R-220 SE Operation Manual, Version F6 OperationThis chapter gives examples of typical instrument applications and instructions on how to

Page 76

6 Operation69 R-220 SE Operation Manual, Version F6.2 Optimal distillation conditionsTo achieve optimal distillation conditions, all distillation ene

Page 77

1 About this manual7 R-220 SE Operation Manual, Version F1 About this manualThis manual describes the Rotavapor R-220 SE and provides all informatio

Page 78

6 Operation70 R-220 SE Operation Manual, Version F6.3 Solvent tableSolvent FormulaMolar mass in g / molEvaporation energy in J / gBoiling point at

Page 79 - 8 Troubleshooting

7 Maintenance and repairs71 R-220 SE Operation Manual, Version F7 Maintenance and repairsThis chapter gives instructions on maintenance work to be p

Page 80

7 Maintenance and repairs72 R-220 SE Operation Manual, Version F7.2 Regular service and checksTo maintain the system in good working order the check

Page 81

7 Maintenance and repairs73 R-220 SE Operation Manual, Version FHeating bathUse a commercially available decalcification agent to dissolve residues of

Page 82

7 Maintenance and repairs74 R-220 SE Operation Manual, Version F7.3 Snap flange coupling, flask seal and vapor ductRemoval / installation of the snap

Page 83

7 Maintenance and repairs75 R-220 SE Operation Manual, Version FRemoval / installation of the flask seal!Vapor duct might slip out!aRemove the snap fla

Page 84 - F1 — F4 (12A, 250V)

7 Maintenance and repairs76 R-220 SE Operation Manual, Version FRemoval / installation of the vapor ductWith the flask seal removed, the (glass) vapor

Page 85 - 9.1 Storage and transport

7 Maintenance and repairs77 R-220 SE Operation Manual, Version F7.4 Distribution head seal and vacuum sealRemoval of the seal holderabcaRemove the s

Page 86 - 9.2 Disposal

7 Maintenance and repairs78 R-220 SE Operation Manual, Version FInstallation of the seal unitabaPlace the vacuum seal onto the seal holder with the r

Page 87 - Health and Safety Clearance

8 Troubleshooting79 R-220 SE Operation Manual, Version F8 TroubleshootingThis chapter helps to resume operation after a problem has occurred with the

Page 88 - 10 Spare parts

2 Safety8 R-220 SE Operation Manual, Version F2 SafetyThis chapter highlights out the safety concept of the instrument and contains general rules of b

Page 89

8 Troubleshooting80 R-220 SE Operation Manual, Version F8.2 Error messages and their remedyThe error messages are shown in the rotational speed displ

Page 90

8 Troubleshooting81 R-220 SE Operation Manual, Version FError Additional error indicator on display Possible cause RemedyE03 Drive unit icon flashes. T

Page 91

8 Troubleshooting82 R-220 SE Operation Manual, Version FError Addition error indicator on display Possible cause RemedyE12 ‘FLOW’ message appears. Coo

Page 92

8 Troubleshooting83 R-220 SE Operation Manual, Version FError Addition error indicator on display Possible cause RemedyE31 Heating bath icon flashes. •

Page 93

8 Troubleshooting84 R-220 SE Operation Manual, Version FError Addition error indicator on display Possible cause RemedyE50 ‘RECORD’ message flashes. No

Page 94

9 Shutdown, storage, transport and disposal85 R-220 SE Operation Manual, Version F9 Shutdown, storage, transport and disposalThis chapter instructs

Page 95

9 Shutdown, storage, transport and disposal86 R-220 SE Operation Manual, Version F9.2 DisposalFor instrument disposal in an environmentally friendly

Page 96

9 Shutdown, storage, transport and disposal87 R-220 SE Operation Manual, Version F Health and Safety Clearance Health and Safety Clearance_20081110.

Page 97

10 Spare parts88 R-220 SE Operation Manual, Version F10 Spare partsThis chapter lists spare parts, accessories and options including their ordering

Page 98

10 Spare parts89 R-220 SE Operation Manual, Version F10.1 Reflux glass configurationsReflux configurations are available with three different types of c

Page 99

2 Safety9 R-220 SE Operation Manual, Version F2.4 Safety warnings and safety signals used in this manualDANGER, WARNING, CAUTION and NOTICE are stand

Page 100 - 10.3 Receiving vessel parts

10 Spare parts90 R-220 SE Operation Manual, Version F10.1.1 'R' configuration041228005155xxx04107604115904134804106004137302727704116202728

Page 101 - 10.4 Miscellaneous parts

10 Spare parts91 R-220 SE Operation Manual, Version F10.1.2 'RB' configurationx041228005155xx0411310278240413480410600413730272770411620272

Page 102 - Part name Order no

10 Spare parts92 R-220 SE Operation Manual, Version F10.1.3 'C' configuration041228005155xx041076025981041348041060041373027277041162027289

Page 103

10 Spare parts93 R-220 SE Operation Manual, Version F10.1.4 'BASIC' configuration041228005155x04107604115911056 021041060110555960272770272

Page 104

10 Spare parts94 R-220 SE Operation Manual, Version F10.2 Decending glass configurationsDecending configurations are available with four different typ

Page 105

10 Spare parts95 R-220 SE Operation Manual, Version F10.2.1 'D' configuration041228005155x0410760411550413480413350272770011690272890411510

Page 106

10 Spare parts96 R-220 SE Operation Manual, Version F10.2.2 'D2 HP' configuration0412280410760413480413350272770413370411300411310007940411

Page 107

10 Spare parts97 R-220 SE Operation Manual, Version F10.2.3 'D2' configuration041228005155x041076y04115904133502727700116902728904115504115

Page 108

10 Spare parts98 R-220 SE Operation Manual, Version F10.2.4 'DB' configuration0412280051550410760413480413350272771105558802728904112004115

Page 109 - F +41 71 394 65 65

10 Spare parts99 R-220 SE Operation Manual, Version F10.2.5 'DB2' configuration041228005155x04113104133502727702728904115504115104113011055